permainan bola saya mau bertanya bagaimana menentukan /rumusnya panjang dan lebar dan juga diameter untuk membuat tangki photo voltaic?
Welds that are unsuccessful to satisfy the criteria provided in paragraph higher than, shall be reworked ahead of hydrostatic screening as follows :
2. in API 12F (specification for store welded tanks for storage of output liquids) joint in bottom plates shall be use double-welded butt joint and for assessment remember to confer with para 5.
Ø Should the ensuing thickness is less than least demanded as per hydrostatic take a look at layout conditions, re-welding is needed.
Taj, on October 16, 2011 at two:31 pm mentioned: expensive Pal ,your website assistance me alot, and thanks helping individuals by your World wide web , and i want to know about tank staircase internal stringer plate gap marking and outer plate gap marking to repair the phase , i obtained drawing although not extremely clearly point out even bought reply from engineering dep that structure at site, i dont know what's the method of staircase radious marking
Selama pekerjaannya sudah sesuai sequence saya pikir tidak akan ada masalah. Untuk mencegah buckling pada waktu fit-up harap dicek peaking banding dan pengelasannya. Mudah2an membantu. Thanks
untuk metode air increasing tidak dijelaskan di API 650 karena itu tergantung metode konstruksi masing2 perusahaan. File metode air raising ada dirumah,.insyaallah besok aq share deh.
...................................................................................................................
9. immediately after end weld from out side check the radius of buckling plate and location yet again employing stiffener and essential plate
Assamualaikum, saya ingin bertanya mengenai peaking & banding. Sekarang saya terlibat dalam kerja membuat storage tank & kaedah yang kami gunakan untuk erect tank adalah jacking approach, that is we really need to erect the tank ranging from prime to base. So we currently completed the 12th class until 11th class such as the roofing. Them my QC actually previously did the peaking and banding for shell plate but a lot of the readings were being exceed the tolerance given in API 650 that's +-13mm.
kalau harus mengacu pada least yS dikarenakan dalam 1 group tidak ada yang sama atau lebih besar minimal YSnya dari FE 52C boleh tidak digantikan oleh substance di group VI yang mempunyai minimum amount YS yang lebih tinggi dari YS group VI.
Iya pak memang tidak saya bikin permainan bola detil,..dan hanya mencakup pada waktu design saja. Makasih atas sarannya.
The badminton participant who was born in Cimahi, of Karo descent, was released to badminton by his father when he was however in kindergarten. He may be the fourth of five young children.
I’m searching for an erection treatment to get a 1000000 barrel storage tank, acc to API 650. is it possible to aid me on this? Thanks in advance in your attenion.
......................................................................................................................